Switchgears
ACB - TINANIA & TITANIA +
- Range: 400 A – 6300 A in 3 Pole & 4 Pole execution, Fixed & Drawout version
- High breaking capacity Ics = 100% Icu upto 150 kA
- Protection against LSIG
- Communication through RS 485 modbus, LCD display
- Advance protections, Power metering, Harmonics & ZSI
- Thermal memory / fault history / max demand / Over Temperature Protection
MCCB
- Range : 16 A- 800 A in 1P /2P/3P/4P execution
- Breaking capacity : 10 kA – 85 kA
- Thermal Magnetic & Microprocessor release
- Compliance Standard : IEC60947-1&2
- High assurance of safety up to 1000 VAC & impulse withstand 8kV
- Operation Voltage up to 690 VAC
- Compact design to optimize panel size
- Positive Isolation & Class II insulation
- Withstanding under high ambient temperature & Harsh
Environment - High mechanical and Electrical endurance for better return on
Investment - Wide range of accessories.
POWERSAFE MCCB PANEL BOARD
- Range250A-630A
- Available in single door & double door version
- Modularconstruction&compactsize.
- Designedforfloor/wallmounting.
- Elegant&sleekinappearance.
INSTASHIFT MANUAL CHANGE OVER SWITCH
- Range 250 A – 630 A
- Available in single door & double door version
- Ready to use customised solution for load management.
- Modular construction & compact size.
- Designed for floor / wall mounting.
- Dedicated shrouded busbar provides safety.
- Elegant & sleek in appearance.
KOMPACT PLUS SWITCH DISCONNECTOR FUSE
- Range : 32 A – 800 A in 3P & 4P.
- Front operated, positive isolation switch mechanism.
- Stationary Fuse Links prevent loosening of fuses.
- Handle with Padlock, Door interlock and defeat facility.
- In open execution / in enclosure.
- With Fuse version also available
EUROLOAD CHANGEOVER SWITCH
- Range : 40 A – 3150 A in 4P execution
- Line and load reversibility
- Quick make and break operation
- High electrical & mechanical endurance
- Enclosed mechanism to avoid dust ingress
- Add on aux. contacts
- Available in open execution / enclosure
EUROLOAD SWITCH DISCONNECTOR
- Range : 80 A – 400 A in 3P execution, 40 A – 3150 A in 4P
execution - High electrical & mechanical endurance
- Quick make and break operation
INSTALINE AUTOMATIC TRANSFER SWITCH
- Range : 40 A – 630 A in 4P execution available with smart
controller - Compact & light weight design
- Positive indication through flag indicator
- Option for source selection
- Start / Stop command for digi set
- Protection against Under / Over Voltage, Under / Over Frequency & Phase Failure
CONTACTORS & THERMAL OVERLOAD RELAY
- Range : 9 A – 800 A, AC-3 in 8 Frames
- Snap fit construction up to 40 A
- Class H Insulation
- Cassette Type Design and universal Coil (AC / DC) from 115 A to 800 A
- Nut Retaining Washer for quick termination
- DIN rail mounting up to 100 A
- Protection degree IP 20
- DC Coil Contactor (9 A – 105 A) and Mini Contactor (7 A – 16 A)
- Thermal Over load class 10 A relays with built in SPP
- Auto Manual reset option
- Direct mounting / separate mounting provision
- Transparent cover for Dust & accidental touch protection
HGSM SERIES MOTOR PROTECTION CIRCUIT BREAKER
- Push Button version – 1 Frame size – 45 mm Width
- Rotary version – 2 Frame size – 45 mm & 55 mm Width
- Ratings from 0.1 A – 63 A, Trip Class 10 A
- Rated Operation Voltage Ui = 690 V
- High Magnetic Setting – Makes it suitable for IE2, IE3 & IE4 Motors
- In-built “Type-2 Co-ordination” even when used standalone
- Finger proof IP20 Terminals
- Lockable in OFF Position
- Suitable for DIN channel mounting
STARTERS
- Motor Starters upto 150 HP in DOL and star delta configuration
in single phase and 3 phase application - Submersible panel solutions with in built auto switch
and advance protection features ( option of MCB incomer
possible) - Wide band coil operation making suitable for Tropical
conditions - High performance long life all purpose contactors and
accurate thermal over load relay for precise protection
CAPACITORS, REACTORS & IPFC
- High Performance low loss MPP Cylindrical/ box power capacitors – Splendid duty, Heavy Duty and super heavy duty in
440 V / 480 V / 525 V - Single phase and Agriculture duty MPP capacitors
- HD Harmonic Detuned reactors from 1 to 100KVAR ( Aluminum & copper ) with upto 225% linearity & H Class Insulation
- Zero programing Intelligent Power factor controller 8 & 12 stage
AUTOMATIC POWER FACTOR CORRECTION PANEL
- Range: 10 kVAr to 1000 kVAr
- Modular Design which allows easier assembly, installation and maintenance by the user.
- Powder coated panel box.
- Advanced Microprocessor based IPFC.
- Switch option Auto or Manual.
- Capacitor Duty Contactor with dumping resistance to enhance
capacitor life
CAPACITORS - MFD
- Rating : 2.25 µF – 120 µF
- casing : Plastic & Aluminium
- Low dissipation factor
- Extended life capacity
- Self healing properties
- Self extinguishing plastic material
IGBT BASED POWER QUALITY SOLUTIONS
- SVG, AHF & Hybrid Power Quality Solutions
- Heavy Duty IGBT used for Switching Technology
- Latest technology & Ultra-Fast algorithm used for sensing and
control which provides smooth & precise compensation. - Advanced LCD display with intelligent 32 bit
microprocessor. - User friendly programs and customization as per customer requirement for data display.
- Modular design enclosure fabricated by latest Amada CNC
Machines & painted through fully automatic powder coating
plant after
CHANGEOVER SWITCH
- Suitable for individual mounting, inner mounting holes and
mounting brackets provided in enclosures. - Sheet steel enclosure duly phosphatised and powder
painted. - Door interlocking facility.
- Termination suitable for Aluminum cables, adequate knockouts
provided in the enclosure for cable entry.
SWITCH FUSE UNIT
- Suitable for surface mounting.
- Sheet steel enclosure duly phosphatised and powder
painted. - Provision of conduit knockouts and detachable gland plates
KITKAT
- Short Circuit breaking capacity upto 16 A-2 kA, 32 A onward 4 kA
- Fuse carrier contacts – Copper Tinned
- Fuse Base contacts – Brass Tinned
- Available in Standard Version & Delux version
- Higher ratings with extension strips
RCCB
- Ensures circuit identification and hence reduces maintenance
downtime - The terminals are suitable for cables up to 35 mm2 cross section
area. Thus making it suitable for copper and aluminium cables - They guide the cable towards the cage terminal and avoid
improper cable termination - Every device is provided with a dual position DIN rail clip, so it
becomes much easier to change a device from a device bank
connected to a bus-bar, without disturbing the existing wiring
PRCD PLUG - RESIDUAL CURRENT DEVICE
- Provide protection from risk of leakage current (life saving)
- Type A: Residual current fault of AC as well as pulsating DC
- In case of fault it disconnects both line and neutral of output
supply - Manual reset and test button for safety checks
- Provide protection from both overload and short circuit
- Protect from possible fire hazards
- Engineered Double pole switching
- Auto trip feature / Indication for power ON
- Manual reset provision to restore supply
- Built-in Test and Reset Buttons
- Compliance to IEC 61540
- Brass current carrying parts
- Compact size
ARC FAULT DETECTION DEVICE (AFDD)
- Provides protection against arc faults, short circuits Overloads,
and Leakage. - Resistant to nuisance tripping i.e. it distinguishes between
normal arcs that can appear at the time of switching and
abnormal arcs that could lead to potential risk of fire. - It offers protection against overvoltage higher than 270 V ± 5%,
thus prevents any damage to electrical appliances. - Contact position indicator is provided in Combined 1P+N MCB
AFDD for fast and easy identification of contact status. Green:
contacts opened Red: contacts closed
DC - MINIATURE CIRCUIT BREAKER
- Range : 16 A, 20 A, 25 A, 32 A, 40 A & 63 A
- Execution : 2P & 4P
- Specification : IEC 60947-2
- Application : MCBs for DC application are specially designed to
meet tough arc quenching conditions. While selecting circuit
breaker for DC applications above parameters have to be taken
into consideration.
SURGE PROTECTION DEVICES
- Visual as well as Remote end-of-life indicators.
- Simple, Professional Installation of Arrester Modules
- High Terminal Capacity – 35 mm2 for Ease of
Installation. - Bi-stable Snap-pusher for Easy Installation and
Extractioin from DIN-rail. - Finger Touch-Proof IP 20.
- TUV Tested and approved. CE compliant.
DOWNSTREAM PROTECTION DEVICES
- Provide protection from the risks of leakage current (life saving).
- All-in-one devices (SRCD DBOXx & HofeSafe SRCD), which also
provide protection from overload & short circuit faults - Manual reset and test button for safety checks.
- In case of fault it disconnects both line & neutral of output supply.
TIME SWITCH
- Digital time switch with daily and weekly program
- Text-oriented user guidance in display
- 3 year power reserve (For multifunction time switch 10 year
power reserve) - Automatic summer/winter time changeover
- Preset date and time
- Holiday program
- Permanent switching ON/OFF for better user experience.
- Reset option
- Programmable in 5 languages
MINIATURE CIRCUIT BREAKER
Range
- 0.5 A to 63 A – ‘C’ Curve & 0.5 A to 32 A – ‘D’ Curve
Accessories :
- Auxiliary Contact
- Under Voltage Trip
- Shunt Trip
- Under Voltage Trip + Time Delayed
- Over Voltage Trip
- Phase Loss
- Under Voltage Trip + Over Voltage Trip
MCB - HIGHER CURRENT MCB (80 A - 125 A)
- Range: 80 A, 100 A & 125 A – ‘C’ Curve
- Execution : Single Pole (1P), Double Pole (2P)
Three Pole (3P), Four Pole (4P) - Specification : IS/IEC 60947-2 & IEC 60947-2